In vivo (Aggiungere i solventi al prodotto singolarmente e in ordine.)
Homogeneous suspension
CMC-NA
≥5mg/ml
Taking the 1 mL working solution as an example, add 5 mg of this product to 1 ml of CMC-Na solution, mix evenly to obtain a homogeneous suspension with a final concentration of 5 mg/ml.
Clear solution
5%DMSO
40%PEG300
5%Tween80
50%ddH2O
Convalidato dai laboratori Selleck. Se sono necessarie modifiche a questa formulazione, contattare il nostro team di vendita per test personalizzati.
4mg/ml
(8.72mM)
Taking the 1 mL working solution as an example, add 50 μL of 80 mg/ml clarified DMSO stock solution to 400 μL of PEG300, mix evenly to clarify it; add 50 μL of Tween80 to the above system, mix evenly to clarify; then continue to add 500 μL of ddH2O to adjust the volume to 1 mL. The mixed solution should be used immediately for optimal results.
* <1 mg/ml significa leggermente solubile o insolubile. * Si prega di notare che Selleck testa la solubilità di tutti i composti internamente e la solubilità effettiva può differire leggermente dai valori pubblicati. Ciò è normale ed è dovuto a leggere variazioni da lotto a lotto. * Spedizione a temperatura ambiente (I test di stabilità mostrano che questo prodotto può essere spedito senza alcuna misura di raffreddamento.)
Preparazione delle soluzioni stock
Attività biologica
Descrizione
RHPS4 (NSC714187) è un potente inibitore della Telomerase a concentrazioni submicromolari.
Target
Telomerase
In vitro
RHPS4 innesca una risposta rapida e potente di DNA Damage/DNA Repair a livello dei telomeri in fibroblasti umani trasformati e cellule di melanoma, caratterizzata dalla formazione di diversi foci telomerici contenenti fattori di risposta al danno del DNA fosforilati γ-H2AX, RAD17 e 53BP1. Ciò dipende dall'enzima di riparazione del DNA ATR, è correlato alla delocalizzazione della proteina protettiva legante il DNA telomerico POT1 ed è antagonizzato dalla sovraespressione di POT1 o TRF2.
In vivo
Nei topi, RHPS4 ha esercitato il suo effetto antitumorale su xenotrapianti di cellule tumorali umane di diverso istotipo mediante danno telomerico e apoptosi delle cellule tumorali. L'inibizione tumorale è stata accompagnata da una forte risposta di DNA Damage/DNA Repair e i tumori che sovraesprimevano POT1 o TRF2 erano resistenti al trattamento con RHPS4.
Human transformed BJ-EHLT fibroblasts and M14 melanoma cells
Concentrazioni
1 μM
Tempo di incubazione
3-8 hours
Metodo
RHPS4, used at a concentration of 1 μM for various times, is added to the cells 24 hours after plating. Cell counts and viability (trypan blue dye exclusion) are determined in each experiment. Caffeine at 10 mM, a dose with no toxic effect on cell viability, is left in the medium for 24 hours. Bleomycin is used at a concentration of 30 mM for 30 minutes.
Transcription-associated topoisomerase 2α (TOP2A) activity is a major effector of cytotoxicity induced by G-quadruplex ligands
[ Elife, 2021, 10e65184]
Studies on the Interactions of 3,11-Difluoro-6,8,13-trimethyl-8H-quino[4,3,2-kl]acridinium and Insulin with the Quadruplex-Forming Oligonucleotide Sequence a2 from the Insulin-Linked Polymorphic Region
[ Molecules, 2021, 26(21)6595]
POLITICA DI RESO
La politica di reso incondizionato di Selleck Chemical garantisce ai nostri clienti unesperienza di acquisto online senza problemi. Se non sei in alcun modo soddisfatto del tuo acquisto, puoi restituire qualsiasi articolo entro 7 giorni dalla ricezione. In caso di problemi di qualità del prodotto, sia relativi al protocollo che al prodotto, puoi restituire qualsiasi articolo entro 365 giorni dalla data di acquisto originale. Si prega di seguire le istruzioni seguenti per la restituzione dei prodotti.
SPEDIZIONE E CONSERVAZIONE
I prodotti Selleck vengono trasportati a temperatura ambiente. Se ricevi il prodotto a temperatura ambiente, ti assicuriamo che il Dipartimento di Ispezione Qualità di Selleck ha condotto esperimenti per verificare che la conservazione a temperatura normale per un mese non influirà sullattività biologica dei prodotti in polvere. Dopo la raccolta, conservare il prodotto secondo le indicazioni descritte nella scheda tecnica. La maggior parte dei prodotti Selleck è stabile nelle condizioni raccomandate.
NON PER USO UMANO, DIAGNOSTICO VETERINARIO O TERAPEUTICO.